Mini split size for a sunroom: BTU chart
BTU per hour with the mini split size in brackets, for an 8-foot ceiling and a moderate climate. Columns: insulated, some glass, mostly glass, all glass, 3-season room. Hot climates add 10%, desert climates 20%.
| Size | Insulated, some glass | Mostly glass | All glass, 3-season room |
|---|---|---|---|
| 10 × 12 ft (120 sq ft) | 5,500 (6,000 BTU) | 6,300 (6,000 BTU) | 7,200 (9,000 BTU) |
| 10 × 15 ft (150 sq ft) | 5,500 (6,000 BTU) | 6,300 (6,000 BTU) | 7,200 (9,000 BTU) |
| 10 × 20 ft (200 sq ft) | 6,600 (9,000 BTU) | 7,600 (9,000 BTU) | 8,600 (9,000 BTU) |
| 12 × 20 ft (240 sq ft) | 6,600 (9,000 BTU) | 7,600 (9,000 BTU) | 8,600 (9,000 BTU) |
| 15 × 20 ft (300 sq ft) | 7,700 (9,000 BTU) | 8,900 (9,000 BTU) | 10,000 (12,000 BTU) |
| 16 × 25 ft (400 sq ft) | 9,900 (12,000 BTU) | 11,400 (12,000 BTU) | 12,900 (18,000 BTU) |
Why a sunroom needs more capacity
Glass lets sunlight straight in and insulates poorly. We treat every sunroom as very sunny (+10%), a mostly-glass room as poorly insulated (+15%) and an all-glass three-season room as uninsulated (+30%). In a hot climate, add another 10% on top.
Roof glazing makes it worse. A polycarbonate or glass roof can add more heat than all the walls together. If yours has one, use the hot climate setting in the calculator below even if your summers are moderate.
Heating a sunroom
Turning a three-season room into a four-season room is one of the most common reasons to install a mini split. Glass loses heat quickly, so in cold climates the heating load can be larger than the cooling load. Choose a cold-climate model and check its heating output at your winter low.
Cutting the load
- Low-e or tinted film on the largest sunny panes.
- Insulated blinds or cellular shades, closed in the afternoon.
- An insulated solid roof in place of polycarbonate, if you are renovating.