BTU Bench

What size mini split for a basement?

Basements stay cooler than the rest of the house because the earth around them shades and insulates the walls. That usually means a smaller mini split than the floor area suggests, and a closer look at heating and humidity.

Answer: a typical 700 sq ft basement needs about 11,300 BTU per hour, which is a 12,000 BTU mini split. The chart below covers other sizes and conditions.

Mini split size for a basement: BTU chart

BTU per hour with the mini split size in brackets, for an 8-foot ceiling and a moderate climate. Columns: fully below ground, walk-out or some windows, poorly sealed. Hot climates add 10%, desert climates 20%.

SizeFully below groundWalk-out or some windowsPoorly sealed
15 × 20 ft (300 sq ft)5,700 (6,000 BTU)7,000 (9,000 BTU)8,000 (9,000 BTU)
20 × 25 ft (500 sq ft)9,700 (12,000 BTU)12,000 (12,000 BTU)13,800 (18,000 BTU)
25 × 28 ft (700 sq ft)11,300 (12,000 BTU)14,000 (18,000 BTU)16,100 (18,000 BTU)
30 × 30 ft (900 sq ft)14,600 (18,000 BTU)18,000 (18,000 BTU)20,700 (24,000 BTU)
25 × 40 ft (1,000 sq ft)14,600 (18,000 BTU)18,000 (18,000 BTU)20,700 (24,000 BTU)
30 × 40 ft (1,200 sq ft)17,000 (18,000 BTU)21,000 (24,000 BTU)24,100 (24,000 BTU)

Basements need less cooling, and often more heating

Walls below grade stay near the ground temperature all year, so a finished basement gains little heat in summer. We model a fully below-ground basement as heavily shaded and well insulated, which takes about 19% off the room chart. A walk-out basement with sliding doors and windows behaves more like an ordinary room.

In winter it is the opposite: concrete walls and floors pull heat out steadily. If the mini split will also heat the basement, check its heating output at your coldest temperature. In cold climates the heating load is often the one that decides the size.

Humidity

Basements are damp. A correctly sized mini split runs long, slow cycles that pull moisture out of the air. An oversized one cools the air quickly and shuts off before it dehumidifies, which is why basements are the worst place to size up. Many units also have a dry mode; very damp basements may still need a dedicated dehumidifier.

Installation notes

  • The indoor head drains condensate by gravity. Below grade there is often nowhere lower to drain to, so plan for a condensate pump.
  • The line set has to run up and out through the rim joist; keep it within the manufacturer's maximum length and lift.
  • An open-plan basement over about 1,000 sq ft, or one split into rooms, is better served by two heads on a multi-zone system.

Check your own basement

The calculator starts with the settings used for the answer above. Change any of them to match your space.

Your space

Units
Or fill in length and width below and we work out the area.
Sun exposure

Your basement

—
BTU per hour
Chart value for this area
—
Area used
—
Same load in tons
—
Recommended: —

Frequently asked questions

What size mini split for a 1,000 sq ft basement?

About 14,600 BTU if it is fully below ground, which is a 18,000 BTU mini split. A walk-out basement with windows needs about 18,000 BTU. If it is divided into rooms, use a head in each main room.

Do I need a mini split in a basement at all?

Many basements stay comfortable in summer without cooling. The common reasons to add one are a finished living space, a home office or gym, damp air, or heating that never reaches the basement in winter.

Should I size a basement mini split for heating?

In cold climates, often yes. Check the unit's heating output at your coldest design temperature. Cold-climate models list it at 5°F.