Mini split size for a basement: BTU chart
BTU per hour with the mini split size in brackets, for an 8-foot ceiling and a moderate climate. Columns: fully below ground, walk-out or some windows, poorly sealed. Hot climates add 10%, desert climates 20%.
| Size | Fully below ground | Walk-out or some windows | Poorly sealed |
|---|---|---|---|
| 15 × 20 ft (300 sq ft) | 5,700 (6,000 BTU) | 7,000 (9,000 BTU) | 8,000 (9,000 BTU) |
| 20 × 25 ft (500 sq ft) | 9,700 (12,000 BTU) | 12,000 (12,000 BTU) | 13,800 (18,000 BTU) |
| 25 × 28 ft (700 sq ft) | 11,300 (12,000 BTU) | 14,000 (18,000 BTU) | 16,100 (18,000 BTU) |
| 30 × 30 ft (900 sq ft) | 14,600 (18,000 BTU) | 18,000 (18,000 BTU) | 20,700 (24,000 BTU) |
| 25 × 40 ft (1,000 sq ft) | 14,600 (18,000 BTU) | 18,000 (18,000 BTU) | 20,700 (24,000 BTU) |
| 30 × 40 ft (1,200 sq ft) | 17,000 (18,000 BTU) | 21,000 (24,000 BTU) | 24,100 (24,000 BTU) |
Basements need less cooling, and often more heating
Walls below grade stay near the ground temperature all year, so a finished basement gains little heat in summer. We model a fully below-ground basement as heavily shaded and well insulated, which takes about 19% off the room chart. A walk-out basement with sliding doors and windows behaves more like an ordinary room.
In winter it is the opposite: concrete walls and floors pull heat out steadily. If the mini split will also heat the basement, check its heating output at your coldest temperature. In cold climates the heating load is often the one that decides the size.
Humidity
Basements are damp. A correctly sized mini split runs long, slow cycles that pull moisture out of the air. An oversized one cools the air quickly and shuts off before it dehumidifies, which is why basements are the worst place to size up. Many units also have a dry mode; very damp basements may still need a dedicated dehumidifier.
Installation notes
- The indoor head drains condensate by gravity. Below grade there is often nowhere lower to drain to, so plan for a condensate pump.
- The line set has to run up and out through the rim joist; keep it within the manufacturer's maximum length and lift.
- An open-plan basement over about 1,000 sq ft, or one split into rooms, is better served by two heads on a multi-zone system.
Check your own basement