Quick answer: a 2,000 sq ft house in a moderate summer climate needs about 36,000 BTU of cooling, a 3 ton heat pump. If winters are cold it also needs about 56,000 BTU of heat at the coldest design temperature, which calls for a cold-climate model or backup heat.
Heat pump size chart
Cooling load for a moderate summer, and heating load in BTU per hour by winter climate. Average insulation, 8-foot ceilings.
| Sq ft | Cooling | Mild | Cool | Cold | Very cold | Severe |
|---|---|---|---|---|---|---|
| 1,000 | 18,000 (1.5 ton) | 16,000 | 22,000 | 28,000 | 34,000 | 42,000 |
| 1,500 | 27,000 (2.5 ton) | 24,000 | 33,000 | 42,000 | 51,000 | 63,000 |
| 2,000 | 36,000 (3 ton) | 32,000 | 44,000 | 56,000 | 68,000 | 84,000 |
| 2,500 | 45,000 (4 ton) | 40,000 | 55,000 | 70,000 | 85,000 | 105,000 |
Reading the result
Size for cooling is the standard tonnage that covers the summer load. Size for heating is the tonnage whose nominal rating matches the winter load. When the heating size is larger, a standard heat pump of the cooling size will need help on the coldest days.
Nominal tonnage is a cooling rating. A 3-ton heat pump delivers about 36,000 BTU of heat in mild weather, but often well under that at 5°F unless it is a cold-climate model. Always compare the heating load with the manufacturer's output at your local design temperature.
Three ways to cover a cold-climate heating load
- Cold-climate heat pump sized for heating. Pick a model whose output at your design temperature meets the load. Variable-speed compressors keep this from short-cycling in summer.
- Size for cooling, add backup heat. Electric heat strips in the air handler cover the last few thousand BTU on the coldest nights. Simple, but expensive to run if used often.
- Dual fuel. A heat pump paired with a gas furnace, which takes over below a set outdoor temperature. Use the furnace size calculator for that half.
How this calculator works
Whole-house loads here use a rule of thumb: BTU per square foot of conditioned floor, chosen by climate, for an 8-foot ceiling and average insulation.
Cooling, by summer climate:
- Cool summers: 15 BTU per sq ft
- Moderate: 18 BTU per sq ft
- Hot: 22 BTU per sq ft
- Very hot or desert: 26 BTU per sq ft
Heating (output needed at the coldest design temperature), by winter climate:
- Mild winters: 16 BTU per sq ft
- Cool winters: 22 BTU per sq ft
- Cold winters: 28 BTU per sq ft
- Very cold: 34 BTU per sq ft
- Severe: 42 BTU per sq ft
Good insulation takes 15% off and poor insulation adds 15%. Ceilings above 8 feet scale the load by the extra height. A very sunny house adds 10% to cooling and a mostly shaded one takes 10% off. Results are rounded to the nearest 100 BTU. A standard size is the smallest one that covers at least 95% of the load.
These figures sit at the careful end of published rules of thumb. Older charts that quote 30 to 60 BTU per square foot for heating, or a ton for every 400 to 500 square feet everywhere, tend to oversize equipment in today's better-insulated homes.
A rule of thumb gets you into the right size range and helps you check a quote. Before buying a central system, ask the contractor for an ACCA Manual J load calculation. It accounts for your windows, orientation, air leakage, ducts and local design temperatures.
Frequently asked questions
What size heat pump do I need?
Start from the cooling load, then check the heating load. A 2,000 sq ft house in a moderate climate needs about 36,000 BTU of cooling, a 3 ton heat pump. In a cold-winter climate the same house needs about 56,000 BTU of heat, so the heat pump must keep up in winter or have backup heat.
Should a heat pump be sized for heating or cooling?
Where winters are mild, size for cooling: the heating load is smaller and an oversized unit dehumidifies poorly in summer. Where winters are cold, the heating load is usually larger. Either choose a cold-climate model whose output at your design temperature covers it, or size for cooling and add electric backup heat for the coldest days.
Does a heat pump lose capacity in cold weather?
Yes. A standard heat pump's heating output drops as the outdoor temperature falls. Cold-climate models hold much more of their capacity, and their spec sheets list output at 17°F and 5°F. Compare those figures, not the nominal rating, with your heating load.
What size heat pump for a 2,000 sq ft house?
About 3 ton for cooling in a moderate climate. The heating load ranges from about 32,000 BTU where winters are mild to 84,000 BTU in the northern states.
Is a mini split a heat pump?
Almost all ductless mini splits sold today are heat pumps. For one room or zone, size it with the mini split size calculator and check its heating output at your winter low.