Cooling BTU per square foot for one room
From the ENERGY STAR room air conditioner chart, 8-foot ceiling, average sun.
| Room size (sq ft) | BTU per hour | BTU per sq ft |
|---|---|---|
| 100 to 150 | 5,000 | 33.3 to 50 |
| 150 to 250 | 6,000 | 24 to 40 |
| 250 to 300 | 7,000 | 23.3 to 28 |
| 300 to 350 | 8,000 | 22.9 to 26.7 |
| 350 to 400 | 9,000 | 22.5 to 25.7 |
| 400 to 450 | 10,000 | 22.2 to 25 |
| 450 to 550 | 12,000 | 21.8 to 26.7 |
| 550 to 700 | 14,000 | 20 to 25.5 |
| 700 to 1,000 | 18,000 | 18 to 25.7 |
| 1,000 to 1,200 | 21,000 | 17.5 to 21 |
| 1,200 to 1,400 | 23,000 | 16.4 to 19.2 |
| 1,400 to 1,500 | 24,000 | 16 to 17.1 |
| 1,500 to 2,000 | 30,000 | 15 to 20 |
| 2,000 to 2,500 | 34,000 | 13.6 to 17 |
Small rooms need more per square foot because walls, windows and people make up a bigger share of the heat for each foot of floor. A 150 sq ft bedroom still has a window, a door and someone in it.
Cooling BTU per square foot for a whole house
| Summer climate | BTU per sq ft | Sq ft per ton |
|---|---|---|
| Cool summers | 15 | 800 |
| Moderate | 18 | 667 |
| Hot | 22 | 545 |
| Desert | 26 | 462 |
Heating BTU per square foot
| Winter climate | BTU per sq ft | Example states |
|---|---|---|
| Mild winters | 16 | Florida, Gulf Coast, south Texas, Arizona |
| Cool winters | 22 | Georgia, the Carolinas, California |
| Cold winters | 28 | Virginia, Kentucky, Missouri, Pacific NW |
| Very cold | 34 | Ohio, Illinois, Pennsylvania, New York |
| Severe | 42 | Minnesota, Wisconsin, Maine, Dakotas |
Heating figures are the heat output needed on the coldest design day, for average insulation and 8-foot ceilings. Divide by a furnace's AFUE to get its input size, or use the furnace size calculator.
When per-square-foot rules fail
- Lots of glass. A sunroom or a wall of west-facing windows can need 50% more cooling than the chart.
- High ceilings. These figures assume 8 feet. A 10-foot ceiling adds about 25%.
- Kitchens and busy rooms. ENERGY STAR adds 4,000 BTU for a kitchen and 600 BTU for each person beyond two.
- Insulation. A well-sealed new house and a drafty old one of the same size can differ by 30% or more.
The BTU calculator applies all of these for a room, and the AC size calculator does the same for a house.
Sizes people look up most
- 300 sq ft room
- 400 sq ft room
- 500 sq ft room
- 600 sq ft room
- 800 sq ft room
- 1,000 sq ft room
- 1,200 sq ft house
- 1,500 sq ft house
- 2,000 sq ft house
Frequently asked questions
How many BTU per square foot do I need for cooling?
About 20 BTU per square foot is the classic shortcut. For single rooms the ENERGY STAR chart gives more for small rooms, around 30 BTU per square foot at 150 sq ft, and less for large open spaces, around 15 at 2,000 sq ft. Whole houses need about 15 to 26 BTU per square foot depending on climate.
How many BTU per square foot for heating?
About 16 BTU per square foot where winters are mild, 28 in a cold-winter climate and up to 42 in the northern states, for a house with average insulation. Well-insulated homes need about 15% less.
How many BTU do I need for 500 square feet?
About 12,000 BTU for one room, from the ENERGY STAR chart. See the 500 sq ft page for sunny rooms and hot climates.
How many BTU do I need for 1,000 square feet?
About 18,000 BTU for one open space, or about 18,000 BTU for a 1,000 sq ft house in a moderate climate. See the 1,000 sq ft house page.