Work out the heating load of your house and the furnace input size it needs at your efficiency rating. Enter the heated floor area, winter climate and insulation.

Your house

Units
Conditioned floor area only. Leave out the garage and an unfinished basement.

Heating load

—
BTU per hour of heat delivered
Furnace input needed
—
Standard furnace size
—
BTU per sq ft
—
Area used
—
Recommended: —

Quick answer: a 2,000 sq ft house in a cold-winter climate needs about 56,000 BTU of heat, which is a 60,000 BTU furnace at 96% AFUE. Where winters are mild, about 32,000 BTU, the smallest common size.

Heating BTU by house size and climate

Heat output needed in BTU per hour, average insulation, 8-foot ceilings. See the full furnace size chart for furnace input sizes.

Sq ftMildCoolColdVery coldSevere
1,00016,00022,00028,00034,00042,000
1,50024,00033,00042,00051,00063,000
2,00032,00044,00056,00068,00084,000
2,50040,00055,00070,00085,000105,000

Input, output and AFUE

The number on a furnace is its input: how much fuel energy it burns per hour. The heat that reaches your rooms is the input times the AFUE rating. Modern condensing furnaces are 95% to 98% AFUE; older or non-condensing units are 80%. That is why the same house can need a 60,000 BTU furnace at 96% and an 80,000 BTU furnace at 80%.

Common furnace sizes

Residential gas furnaces usually come in 40,000, 60,000, 80,000, 100,000 and 120,000 BTU input, and many brands also sell steps in between such as 45,000, 70,000 or 90,000. If your load falls just above a size, look for an in-between model or a two-stage or modulating furnace, which runs at low fire most of the time.

How this calculator works

Whole-house loads here use a rule of thumb: BTU per square foot of conditioned floor, chosen by climate, for an 8-foot ceiling and average insulation.

Heating (output needed at the coldest design temperature), by winter climate:

  • Mild winters: 16 BTU per sq ft
  • Cool winters: 22 BTU per sq ft
  • Cold winters: 28 BTU per sq ft
  • Very cold: 34 BTU per sq ft
  • Severe: 42 BTU per sq ft

Good insulation takes 15% off and poor insulation adds 15%. Ceilings above 8 feet scale the load by the extra height. Results are rounded to the nearest 100 BTU. A standard size is the smallest one that covers at least 95% of the load.

These figures sit at the careful end of published rules of thumb. Older charts that quote 30 to 60 BTU per square foot for heating, or a ton for every 400 to 500 square feet everywhere, tend to oversize equipment in today's better-insulated homes.

A rule of thumb gets you into the right size range and helps you check a quote. Before buying a central system, ask the contractor for an ACCA Manual J load calculation. It accounts for your windows, orientation, air leakage, ducts and local design temperatures.

Frequently asked questions

What size furnace do I need?

Multiply your heated floor area by the heating factor for your climate: about 22 BTU per square foot where winters are cool, 28 where they are cold and 34 to 42 in the northern states. Then divide by the furnace's AFUE to get the input rating.

What size furnace for a 1,500 sq ft house?

In a cold-winter climate, about 42,000 BTU of heat output, which a 60,000 BTU input furnace covers at 96% AFUE. In the northern states, about 63,000 BTU.

Is the furnace size the input or the output?

Furnaces are sold by input rating, the gas they burn per hour. Heat delivered to the house is input times AFUE. A 60,000 BTU furnace at 96% AFUE delivers about 57,600 BTU; at 80% it delivers 48,000 BTU.

Is a bigger furnace better?

No. An oversized furnace heats the house in short, noisy bursts, with more temperature swings and more wear. Many existing furnaces are oversized. A Manual J calculation often supports a smaller unit than the one being replaced.

Do I need the same size furnace as my old one?

Not necessarily. If the house has had new windows, insulation or air sealing, or the old unit was oversized, the right size may be smaller. Ask the contractor how they sized it.