BTU Bench

What size mini split for an attic room?

Attic bedrooms and bonus rooms sit right under the roof, the hottest part of the house in summer. They need more cooling than a room of the same size downstairs.

Answer: a typical 300 sq ft attic room needs about 7,700 BTU per hour, which is a 9,000 BTU mini split. The chart below covers other sizes and conditions.

Mini split size for a attic room: BTU chart

BTU per hour with the mini split size in brackets, for an 8-foot ceiling and a moderate climate. Columns: well-insulated roof, average, poorly insulated roof. Hot climates add 10%, desert climates 20%.

SizeWell-insulated roofAveragePoorly insulated roof
10 × 15 ft (150 sq ft)5,000 (6,000 BTU)5,500 (6,000 BTU)6,300 (6,000 BTU)
10 × 20 ft (200 sq ft)5,900 (6,000 BTU)6,600 (9,000 BTU)7,600 (9,000 BTU)
15 × 20 ft (300 sq ft)6,900 (9,000 BTU)7,700 (9,000 BTU)8,900 (9,000 BTU)
20 × 20 ft (400 sq ft)8,900 (9,000 BTU)9,900 (12,000 BTU)11,400 (12,000 BTU)
20 × 25 ft (500 sq ft)11,900 (12,000 BTU)13,200 (18,000 BTU)15,200 (18,000 BTU)
20 × 30 ft (600 sq ft)13,900 (18,000 BTU)15,400 (18,000 BTU)17,700 (18,000 BTU)

Why attic rooms run hot

The sun heats the roof all afternoon, and in an attic room the roof is the ceiling, often with only a thin layer of insulation behind sloped drywall. Warm air from the rest of the house also rises into it. We treat every attic room as very sunny (+10%) and adjust for how well the roof is insulated.

Sloped ceilings mean less air volume than a flat 8-foot ceiling of the same floor area, but the hot roof surface more than makes up for it. Use the floor area and don't reduce it for the slope.

Where to put the head

  • On a gable end wall, where there is full height and the line set can run straight outside.
  • Not on a knee wall below the slope, where the airflow hits the ceiling straight away.
  • Keep the line set and condensate drain within the manufacturer's maximum length and lift; attic rooms are often far from the outdoor unit.

Adding insulation to the roof slope, or a radiant barrier, is one of the few upgrades that changes an attic room's load a lot.

Check your own attic room

The calculator starts with the settings used for the answer above. Change any of them to match your space.

Your space

Units
Or fill in length and width below and we work out the area.
Sun exposure

Your attic room

—
BTU per hour
Chart value for this area
—
Area used
—
Same load in tons
—
Recommended: —

Frequently asked questions

What size mini split for a 300 sq ft attic room?

About 7,700 BTU with average roof insulation, which is a 9,000 BTU mini split. With a poorly insulated roof, about 8,900 BTU (9,000 BTU).

Why is my upstairs bonus room so hot?

It is under the roof, warm air rises into it, and it is often at the end of a long duct run from the central system. A dedicated mini split solves all three.

Can I use a window AC in an attic room?

If it has a suitable window, yes. Many attic rooms only have small or gable windows, which is one reason mini splits are popular there.